We are Reverie....
Contact Info
Location House No: 95, Block: B, Road: 4, Dhaka
Follow Us

Low Voltage Solutions

Reverie Power High Voltage Substation Engineering
EPC Excellence
Design • Manufacturing • Commissioning
ABOUT REVERIE POWER & AUTOMATION ENGINEERING LTD

Power Engineering Partner for Utilities, Heavy Industries & Commercial Grids

Reverie Power & Automation Engineering Ltd. is a leading electrical engineering organization specializing in turnkey Medium Voltage (MV) substation infrastructure, custom low and medium voltage switchgear manufacturing, transformer supply, and digital power automation.

With deep expertise in handling complex electrical distribution requirements, Reverie Power delivers end-to-end engineering services—from network design and short-circuit calculation to procurement, civil erection, site testing, and utility grid interconnection. Our solutions strictly adhere to international quality protocols, guaranteeing personal safety, operational reliability, and maximum system availability.

Custom System Design

Tailored busbar arrangements, internal arc classifications, and spatial optimizations.

Smart Substation Automation

IEC 61850 protocol integration with numerical relays, RTUs, and SCADA monitoring.

Rigorous Quality Testing

Comprehensive Factory Acceptance Testing (FAT) & Site Acceptance Testing (SAT).

MEDIUM VOLTAGE PORTFOLIO

Core Substation Engineering Solutions

Comprehensive equipment, assemblies, and turnkey systems engineered for 11kV, 22kV, and 33kV electrical networks.

AIS Switchgear Panel
11kV / 33kV AIS

Air Insulated Switchgear (AIS) Panels

Metal-clad, compartmentalized indoor Air Insulated Switchgear panels equipped with drawout Vacuum Circuit Breakers (VCB). Designed for primary sub-distribution and industrial main substations.

Technical Specifications
  • Rated Current: 630A up to 3150A
  • Short-Circuit Current: 25kA / 31.5kA (3s)
  • Loss of Service Continuity: LSC2B-PM
  • Internal Arc Classification: AFLR 31.5kA 1s
IEC 62271-200 VCB Drawout Interlocked
Gas Insulated Switchgear and RMU
11kV / 22kV / 33kV GIS

Gas Insulated Switchgear & RMU

Compact SF6 sealed stainless steel tank Ring Main Units (RMU) and Gas Insulated Switchgear (GIS) engineered for space-constrained installations, harsh industrial environments, and underground networks.

Technical Specifications
  • Configurations: C, K, V, T (Expandable)
  • Hermetically Sealed IP67 Stainless Tank
  • Maintenance-Free Contact System
  • Smart Motorized Remote Switching Ready
SF6 Sealed Compact Footprint IEC 62271-102
Power Transformer Units
Up to 25 MVA

Power & Distribution Transformers

Heavy-duty Oil-Immersed and Cast Resin Dry-Type (CRT) transformers with On-Load Tap Changers (OLTC) or Off-Circuit Tap Changers (OCTC) for reliable stepping down from 33kV to 11kV or 0.415kV.

Technical Specifications
  • Capacity Range: 250kVA to 25MVA
  • Vector Groups: Dyn11, Ynd11, Dyn1
  • Cooling: ONAN / ONAF / AN / AF
  • Low Core Loss High Grade CRGO Steel
IEC 60076 OLTC / OCTC Dry & Oil Type
Compact Prefabricated Substation
Package Substation

Compact Prefabricated Substation (CSS)

Fully factory-assembled, outdoor weather-proof metallic or concrete enclosures housing the Medium Voltage RMU, Distribution Transformer, and Low Voltage distribution panel in segregated compartments.

Technical Specifications
  • Ingress Protection: IP54 (Equipment) / IP23 (Transformer)
  • Enclosure Class: Class 10 / Class 15 thermal insulation
  • Internal Arc Tested Assembly
  • Plug-and-Play Quick Site Installation
IEC 62271-202 Outdoor Kiosk Pre-Commissioned
SCADA Control & Relay Panel
IEC 61850 Automation

Protection Control & SCADA Automation

Integrated Relay Control Panels (CRP) equipped with microprocessor numerical protection relays, Remote Terminal Units (RTUs), gateway servers, and fiber-optic communication architecture for smart grid management.

Technical Specifications
  • Protocols: IEC 61850, IEC 60870-5-104, Modbus
  • Protection: Overcurrent, Earth Fault, Differential
  • Real-time Fault Recording & Disturbance Analysis
  • HMI Touch Control Screen Interface
Numerical Relay SCADA RTU GOOSE Messaging
High Voltage Testing and Diagnostic Services
Site Commissioning

High Voltage Testing & Retrofitting

Comprehensive site diagnostic services including VLF cable insulation testing, transformer oil dielectric withstand test, relay secondary injection, primary current injection, and legacy switchgear VCB retrofits.

Technical Specifications
  • VLF Cable Hipot Testing up to 60kV
  • Transformer Turns Ratio (TTR) & Winding Resistance
  • Micro-Ohm Contact Resistance Measurement
  • Circuit Breaker Timing & Motion Analysis
VLF Hipot Relay Calibration Life Extension
COMPLIANCE & ACCREDITATION

International Technical Compliance Framework

Every Medium Voltage solution from Reverie Power complies strictly with global electrotechnical standard specifications.

IEC 62271 Series

High Voltage Switchgear

Defines design, insulation withstand levels, temperature rise, and short-circuit capability for AC metal-enclosed switchgears.

IEC 60076

Power Transformers

Governs rating requirements, winding insulation test voltages, temperature rise limits, and loss evaluation for power units.

IEC 61850

Substation Automation

Standard for communications networks and systems in substations, enabling seamless GOOSE messaging between Intelligent Electronic Devices.

ISO 9001:2015

Quality Management

Certified engineering quality management system governing procurement, manufacturing quality control, assembly, and field testing.

COMPLETE EPC SCOPE

End-to-End Substation Execution Process

Reverie Power manages every step of the substation lifecycle. From initial power flow modeling and load growth calculations to physical installation and energization handover.

01

Single Line Diagram (SLD)

System architecture modeling, short-circuit calculations, and protection coordination studies.

02

Precision Assembly

Panel sheet fabrication, busbar bending, wiring harness, and Factory Acceptance Testing (FAT).

03

Civil & Field Works

Transformer foundation pads, earthing grid mesh, control room construction, and cable tray laying.

04

Energization & Handover

Cold and hot commissioning, utility authority approval, as-built documentation, and training.